Trouver Débitmètre à Ultrasons, Débitmètre à Ultrasons Fixe, Débitmètre dans le répertoire Industry, Reliable Fabricant / Fournisseur / Factory de Chine
nouveaux produits
Délai de livraison: | 3 jours |
---|
Modèle: fixed ultrasonic flowmeter/ultrasonic water flow meter(clamp on)
Packaging Detail: | Paper Carton, with 1 set main unit, 5 meter *2 shielded transducer cable(standard), 1pair of sensors(Clamp-on / Insertion type) in it. |
Delivery Detail: | 10 workdays after reciept of payment |
1. Operating Power: |
AC 85—264V or isolation DC 24V |
2. Current: |
50mA(under the condition of connection without keyboard display and alarm of beeper) |
3. Signal Output : |
*One channel standard isolation RS485 output *One channel isolation 4-20mA or 0-20mA active output. *One channel OCT output [programmed between the pulse width(6-1000ms), default before leaving factory (200ms)] *One channel isolation relay output, with positive, negative, net totaliser pulses and different alarm signals. |
4. Signal Input: |
*Two channel three wire system PT100 platinum resistor input loop, to make heat meter has the function of displaying heat quantity. *Three channel 4-20mA input optional,accuracy:0.1%, has the ability to input the signals of pressure, liquid level, temperature and so on. |
5. Display: |
2×20 backlit LCD(Chinese and English optional) |
6. Operating: |
4×4 tactile keypad or magnetic 4 keypads operating(F4 mainframe) |
7. Other Functions: |
*Automatic memory the positive, negative, net totaliser or flow rate and thermal energy of the last 512 days, 128months, 10years *Automatic memory the time of power turning on and off and flow rate of the last 30 times, realize to compensate by hand or automatically read the datas through Modbus communication protocol. |
8. Protection Level: |
*Mainframe: IP65 *Transducer: IP68 |
9. Ex-proof: |
EXd Ⅱ BT4(TDS-100F2 type) |
Technical parameters |
B-type insertion wetted transducer(direct insertion) |
C-type insertion wetted Transducer(oblique insertion ) |
Cement insertion wetted transducer |
Pipe size |
More than DN80mm |
||
Material |
Ball valve and transducer pole’s material: stainless steel, Valve base’s material is carbon steel (stainless steel is optional) |
||
Frequency |
1MHZ |
||
Pipe material |
All metals,most plastics,fiber glass,etc, |
||
Installation method |
Z method |
||
Application of temperature |
-40°C-160°C |
||
bore Size |
φ19mm(please use the manufacture’s dedicated tools to drill,it can install with pressure.) |
||
Pressure class |
1.6MPa(less than 0.8MPa when installing) |
||
Protection class |
IP68(can work in water, and water depth≤3 meter) |
||
Mounting Space |
More than 550mm between the well wall and the pipe wall |
more than 360mm between the well wall and the pipe wall |
more than 700mm between the well wall and the pipe wall |
Length |
186mm |
228mm |
330mm |
Liquid types |
Water,sea water.waste water,chemical liquids,oil,crude oil,alcohol,beer,etc. |
||
Suspension concentration |
≤20000ppm,may contain very small amount of air bubbles. |
||
Dedicated shielded transducer cable |
Shielded transducer cable,can be extended to 500meter×2 contact the manufacturer for longer cable requirement |
Technical parameters |
B-type insertion wetted transducer(direct insertion) |
C-type insertion wetted Transducer(oblique insertion ) |
Cement insertion wetted transducer |
Pipe size |
More than DN80mm |
||
Material |
Ball valve and transducer pole’s material: stainless steel, Valve base’s material is carbon steel (stainless steel is optional) |
||
Frequency |
1MHZ |
||
Pipe material |
All metals,most plastics,fiber glass,etc, |
||
Installation method |
Z method |
||
Application of temperature |
-40°C-160°C |
||
bore Size |
φ19mm(please use the manufacture’s dedicated tools to drill,it can install with pressure.) |
||
Pressure class |
1.6MPa(less than 0.8MPa when installing) |
||
Protection class |
IP68(can work in water, and water depth≤3 meter) |
||
Mounting Space |
More than 550mm between the well wall and the pipe wall |
more than 360mm between the well wall and the pipe wall |
more than 700mm between the well wall and the pipe wall |
Length |
186mm |
228mm |
330mm |
Liquid types |
Water,sea water.waste water,chemical liquids,oil,crude oil,alcohol,beer,etc. |
||
Suspension concentration |
≤20000ppm,may contain very small amount of air bubbles. |
||
Dedicated shielded transducer cable |
Shielded transducer cable,can be extended to 500meter×2 contact the manufacturer for longer cable requirement |
Technical parameters |
Articulate type transducer |
PI-type transducer |
Standard pipe transducer |
|
Main unit |
Integrative type ,wall-mount, transmission ,module |
Integrative type ,wall-mount, transmission, module, water meter |
||
Pipe size |
DN25-DN80mm |
DN15-DN40 |
DN50-DN1000 |
|
Material |
stainless steel |
carbon steel (stainless steel is optional) |
||
Frequency |
1MHZ |
|||
Connection |
articulate type |
flange type |
||
Application of temperature |
-40°C-160°C |
|||
Calibration |
Calibrate with the main unit |
|||
Protection class |
IP68(can work in water, and water depth≤3 meter) |
|||
Dimension |
refer to the following table |
|||
Nominal pressure |
refer to the following table |
|||
Liquid types |
Water,sea water.waste water,chemical liquids,oil,crude oil,alcohol,beer,etc. |
|||
Suspension concentration |
≤2000ppm,may contain very small amount of air bubbles. |
|||
Dedicated shielded transducer cable |
Shielded transducer cable,can be extended to 500 meter×2, contact the manufacturer for longer cable requirement. |
Groupes de Produits : Débitmètre à ultrasons > Débitmètre à ultrasons fixe